CLAAS Jaguar Fault Codes DTC
Code Module Fault Operating state Troubleshooting
E-1 Device
CAB
oil pressure
engine too
poor
E-2 device
CAB
Oil Level
engine too
low
E-3 Unit
CAB
Water pump
defective
Charging Control lights
and goes out.
Test drive
water pump and
generator.
Check control
charge on
generator
.
The apparatus E-4
CAB
Temperature
cooling water
too high
The device E-5
CAB
hydraulic temperature
Coil too
high
The device E-6
CAB
Tighten the handbrake
E-8 Elektrogid
ravlicheski
First drive
running
of the EFA
Wrong voltage
potentiometer supply
of movement
E-11 apparatus
CAB
pressure hydraulics
Coil or
oil level is too
low
E-12 apparatus
CAB
Temperature
charge air
too high
E-13 Metal detector ESR
defective
E-14 ESR metal detector
interrupt
E-15 apparatus
CAB
Reserve SAB
E-16 ESR still connected
adapter box SFM
(Note: SFM =
self-propelled mower)
When
necessity
check
configuration (SFH
or SFM
E-17 numbers of revolutions ESR Sensor
feeder
defective
Check
plug
to compound
sensor and cable
compound.
E-18 numbers of revolutions ESR Sensor
feeder
defective
Check
plug
to compound
sensor and cable
compound.
E-19 apparatus
CAB
Hydraulic
drive motor
Coil not
complies
configuration
E-20 Elektrogid
ravlicheski
First drive
running
of the EFA
new module EFA =>
absolutely necessary
potentiometer study
movement of the lever
This message appears
after installing a new
EFA module when the
ignition.
After learning
potentiometers arm
and hydraulic motion
flow this message
no longer appears.
1. Study
potentiometer
movement of the lever
2. Study
hydraulic
flows through
CDS system
Hydraulic
oil should have
labor
temperature.
meaning
voltage
pressure sensors
should be <1.2 V.
E-25 ESR fault downstream
hydraulic pump
feeder
E-27 Elektrogid
ravlicheski
First drive
running
of the EFA
Defective valve output
PWM trailer brakes
E-30 In ESR Valves
stop permanently
energized
E-32 device
CAB
CAN-Bridge Module
defective
Check
power
module.
Check strength
landing and contact
conclusions.
E-33 ESR ESR module defective Check
power
module.
Check strength
landing and contact
conclusions.
E-34 AutoContour
CAC
module outline
faulty system
Check
power
module.
Check strength
landing and contact
conclusions.
E-36 module GGS GGS Defect Test
power
module.
Check strength
landing and contact
conclusions.
E-37 Elektrogid
ravlicheski
First drive
running
of the EFA
EFA faulty module Emergency stop:
During this work
It indicates a defect
power module output.
It should be shut down.
The movement of the machine
no more
provided
possible.
Turn off the machine and
restart,
if the fault
no more
It appears,
in another module
procedure, otherwise
If not, replace
module.
E-38 KSR Control Unit
valve defective
E-39 ATP reserve, autopilot
E-40 Elektrogid
ravlicheski
First drive
running
of the EFA
Faulty valve
hydraulic pump
Emergency mode:
The machine moves only
reversing at speeds
OK. 2 km / h at the 2nd
Transfer 1 km / h in the 1st
transmission.
When you identify short
the closure of the valve
It made an emergency
Stop the movement over
impossible.
flap
impossible
to govern:
Check
cable
Connect to
valve. Check
the module output.
measure
resistance
coil range
values: 6 - 12 ohms
Check
plug
to compound
valve.
E-41 Elektrogid
ravlicheski
First drive
running
of the EFA
Faulty
electromagnetic
hydraulic valve
engine
Limited
exploitation:
Stir until
Max. 7 km / h on the 1st
transmission,
ok.12 km / h on the 2nd
transfer
flap
impossible
to govern:
Check
cable
module connection to
the valve for a short
circuit or
breakage. Check
the module output.
measure
resistance
coil range
values: 6 - 12 ohms
Check
plug
to compound
valve.
E-42 Elektrogid
ravlicheski
First drive
running
of the EFA
Faulty third magnet
electromagnetic
valve
Emergency Stop:
The machine moves on
coast to stop,
further movement is not
provided
possible.
flap
impossible
to govern:
Check
cable
module connection to
the valve for a short
circuit or
breakage. Check
the module output.
measure
resistance
coil range
values: 6 - 12 ohms
Check
plug
to compound
valve.
E-43 Elektrogid
ravlicheski
First drive
running
of the EFA
Defect
electromagnetic
pump valve
motion ago
Emergency mode:
The machine moves only
forward at approx. 2
km / h at the 2nd transmission 1
km / h on the 1st gear
When you identify short
the closure of the valve
It made an emergency
Stop the movement over
impossible.
flap
impossible
to govern:
Check
cable
module connection to
the valve for a short
circuit or
breakage. Check
the module output.
measure
resistance
coil range
values: 6 - 12 ohms
Check
plug
to compound
valve.
E-44 device
CAB
Out of order
communication
engine system
No CAN bus to
module ADM.
The module works
wrong.
Check
power
modules. Check
cable trunk to
modules (terminals).
E-45 Grinder GGS
not in the initial position
E-46 Elektrogid
ravlicheski
First drive
running
of the EFA
Faulty
lever potentiometer
of movement
Emergency mode:
The car moves with
speed 1 km / hr only
in the forward direction.
(Identification of areas
movement through
neutral switch
position and the switch
Reverse)
Potentiometer
movement of the lever
It is in the form
double
potentiometer.
Signal
malfunction
issued
following cases:
Incorrect
polarity
potentiometers
movement, open
cable
complete,
defective
contact strip
potentiometer.
Remedy:
Check supply
voltage
potentiometer
motion check
plug
to compound
potentiometer.
No comments:
Post a Comment